CROWDCOUNTER Technology
Display
and Interface Unit, Technical Data
.
OverHead Sensor & Display / Report
Unit
General: This unit
provides the data reporting for the Overhead Sensors. All data and power is
routed through this unit through the standard DB15 X cable (supplied) . The People Count data is available for each
daisy chained section in two ways: by
Fluorescent Data Display, and on a standard RS232C serial data link.
Overhead People Counter Interface:
Standard unit provides power and data reporting from one complete daisy chained section of sensors. The daisy chain can be extended to ANY number.
Fluorescent Data Display:
Time: In Digital Hour / Minute / Seconds format, updated each second.
(Must be initialized through Serial Link)
Serial Interface link: RS 232 C (modem compatible) on standard DB9 connector
at 2400 baud (modified to other rates
at no charge). Counts can be accessed by connection directly to
PC, or by dial-up modem, or physically seen on the fluorescent display. Optional non-volatile memory stores counts
in one minute, 10 minute 1 hour, or one day increments. Over 2 years of passage data (hourly
increments) can be stored in this memory.
Serial Software Commands:
T selects Time Increments
R Reports present counts
D Data dump of stored
count log with date & time stamps.
B Initiates System
Built-In-Test
H Initiates High Security
mode

Data readout on PC uses standard Microsoft Windows ® Hyperterminal
Electrical: 12 V DC,
1 amp plus 400 mA per daisy chained Overhead sensor. 12 V Power supply provides power to this
unit and all Overhead Sensor Units connected to it in a daisy chain. Battery backup for UPS recommended.
Size: 15 X 12 X 2.5
inches
Weight: Under 15 pounds
(7 kG)